{"title":"Rotors","description":"\u003cp class=\"p1\"\u003eBeckman Coulter centrifuge and ultracentrifuge rotors, rotor accessories, and related labware. Includes fixed-angle and swinging-bucket rotors such as the JA-17, JA-14.50, JLA-10.500, JLA-16.250, JLA-8.1000, and SW 41 Ti. All rotors are inspected and certified before shipment.\u003c\/p\u003e","products":[{"product_id":"ja-1450-rotor","title":"Beckman Coulter JA-14.50 rotor assembly, biosafe (with dual-locking lid) - INSPECTED","description":"\u003cp\u003eThe JA14.50 Tapered Rotor Assy, Bio-Contained fixed-angle rotor comes complete with a secure dual-locking lid and is constructed from high-grade aluminum. This rotor is not only lightweight but also versatile, ideal for a variety of applications including pelleting and density gradient separations. It is perfectly suited for the separation of proteins, lysate and tissue homogenates, nucleic acids, cells, viruses, and blood components. Designed to be used with the Avanti J Series centrifuges, it enhances the efficiency and productivity of your laboratory processes.\u003c\/p\u003e\u003cp\u003eOur JA-14.50 rotor assembly (DATE OF MFG. 04\/21), biosafe (with dual-locking lid), can be quoted alongside our \u003ca href=\"\/products\/refurbished-avantijxn\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eBeckman Coulter Avanti JXN-30 Centrifuge\u003c\/strong\u003e\u003c\/a\u003e. Contact Service AI for current availability and pricing for the rotor alone or a centrifuge-and-rotor package tailored to your laboratory's workflow.\u003c\/p\u003e\u003ch3\u003eSalient Features of the JA-14.50 Fixed-Angle Rotor\u003c\/h3\u003e\u003cp\u003eThe JA-14.50 Fixed-Angle Rotor is designed for use with Beckman Coulter Avanti J Series centrifuges. It is suitable for a wide range of applications, including pelleting cells, bacteria, and food products, as well as separating proteins, viruses, and subcellular fractions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eMaximum Speed:\u003c\/strong\u003e 14,000 RPM\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eMaximum Relative Centrifugal Force (RCF):\u003c\/strong\u003e 35,000 × g at maximum radius\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Capacity:\u003c\/strong\u003e 16 tubes, each with a capacity of 50 mL\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Angle:\u003c\/strong\u003e 35 degrees\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Anodized aluminum rotor body with Buna-N and ethylene propylene rubber O-rings\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eNominal Rotor Capacity:\u003c\/strong\u003e 800 mL\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDesign and Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eDual-Locking and Single-Locking Lid Options:\u003c\/strong\u003e The rotor is available with either a dual-locking or single-locking lid for secure operation. The dual-locking lid allows for safe tube handling under a safety hood.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eFluid-Containment Annulus:\u003c\/strong\u003e The patented design helps retain liquid that may escape from overfilled or leaking tubes, minimizing the risk of contamination.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Ideal for pelleting, phase separation, and binding studies. The rotor can also be used for high-speed centrifugation of biological samples.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaintenance and Care:\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eLubrication:\u003c\/strong\u003e Regularly apply Spinkote lubricant to metal threads and silicone vacuum grease to O-rings to maintain sealing integrity.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eCleaning:\u003c\/strong\u003e Wash the rotor with a mild detergent such as Solution 555, rinse with distilled water, and air-dry. Avoid using acetone or harsh chemicals.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eDecontamination:\u003c\/strong\u003e Use RadCon Surface Spray, IsoClean Solution, or Radiacwash for decontamination, following proper safety protocols.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePart Numbers for the JA-14.50 Rotor Assembly\u003c\/h3\u003e\u003col data-rte-list=\"true\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRotor Assembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eJA-14.50 Rotor Assembly with dual-locking lid:\u003c\/strong\u003e B88554\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eJA-14.50 Rotor Assembly with single-locking lid:\u003c\/strong\u003e B88555\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLid and O-rings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eDual-locking lid:\u003c\/strong\u003e B19947\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSingle-locking lid:\u003c\/strong\u003e B19952\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eLarge O-ring (Buna-N rubber):\u003c\/strong\u003e 885501\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSmall O-ring (ethylene propylene rubber):\u003c\/strong\u003e 961696\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLubrication and Cleaning Supplies:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSpinkote Lubricant (2 oz):\u003c\/strong\u003e 306812\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSilicone Vacuum Grease (1 oz):\u003c\/strong\u003e 335148\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSolution 555 (1 qt):\u003c\/strong\u003e 339555\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Cleaning Kit:\u003c\/strong\u003e 339558\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003e\u003cstrong\u003eSource:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eTitle:\u003c\/strong\u003e JA-14.50 Fixed-Angle Rotor Manual\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003ePublisher:\u003c\/strong\u003e Beckman Coulter, Inc.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003ePublication Date:\u003c\/strong\u003e May 2023\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eDocument ID:\u003c\/strong\u003e B32164AE\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis manual provides comprehensive safety, operation, and maintenance instructions for the JA-14.50 Fixed-Angle Rotor, ensuring reliable and safe operation in Beckman Coulter centrifuges.\u003c\/p\u003e\n\u003ch3\u003eJA-14.50 Applications: LabPundit Reading\u003c\/h3\u003e\n\u003cp\u003eWith sixteen 50 mL positions and an 800 mL nominal capacity, the JA-14.50 provides a configuration for laboratories processing multiple samples within established pelleting and separation protocols. LabPundit's \u003ca href=\"\/blogs\/guide-to-centrifugation\/maximize-laboratory-efficiency-with-the-beckman-coulter-avanti-jxn-30-centrifuge-and-ja-1450-rotor\" target=\"_blank\" rel=\"noopener\"\u003eAvanti JXN-30 and JA-14.50 application overview\u003c\/a\u003e discusses cell pelleting, clarification of suspensions, and related workflow considerations.\u003c\/p\u003e\n\u003ch3\u003eRotor Selection and Labware Configuration\u003c\/h3\u003e\n\u003cp\u003eSeparation objectives, required RCF, sample volume, and tube or adapter configuration together determine the appropriate operating conditions. The JA-14.50 manual provides the applicable labware combinations and operating limits, including adjustments for sample density. For broader context on rotor geometry and configuration choices, see \u003ca href=\"\/blogs\/guide-to-centrifugation\/the-start-up-researchers-guide-to-centrifuge-rotors\" target=\"_blank\" rel=\"noopener\"\u003eA Startup Guide to Centrifuge Rotors\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRotor Care and Lifecycle Planning\u003c\/h3\u003e\n\u003cp\u003eCleaning methods, inspection criteria, and service-life requirements are specific to the rotor design. The assembly's manufacture date is one part of its history; condition and manufacturer-defined service limits remain relevant to lifecycle planning. LabPundit's \u003ca href=\"\/blogs\/guide-to-centrifugation\/the-complete-guide-to-centrifuge-rotor-care-inspection-and-retirement\" target=\"_blank\" rel=\"noopener\"\u003eComplete Guide to Centrifuge Rotor Care, Inspection, and Retirement\u003c\/a\u003e provides context on storage, corrosion, inspection, and retirement considerations. Evidence of cracking, pitting, or other damage warrants withdrawal from service pending a qualified assessment.\u003c\/p\u003e\n\u003ch3\u003eCentrifugation Reference Resources\u003c\/h3\u003e\n\u003cp\u003eOur \u003ca href=\"\/blogs\/guide-to-centrifugation\/centrifuge-faq-essential-information-for-users\" target=\"_blank\" rel=\"noopener\"\u003eCentrifuge FAQ: Essential Information for Users\u003c\/a\u003e brings together reference information on RPM and RCF, tube fill volumes, consumable reuse, and rotor identification. These articles complement the current rotor, centrifuge, and labware manuals, which remain the primary references for operating procedures.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333359394953,"sku":"SQB88554","price":9800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/IMG_2452.webp?v=1772367413"},{"product_id":"ja-17-rotor-assembly","title":"Beckman Coulter JA-17 Fixed Angle Rotor - INSPECTED","description":"\u003cp\u003eThe JA-17 rotor is a high-performance fixed-angle rotor designed for use with Beckman Coulter J2, J6, and Avanti® J Series centrifuges. It is ideal for a variety of centrifugation applications, including pelleting cells, subcellular particles, and cell membranes.\u003c\/p\u003e\u003cp\u003eOur sparingly used \u003cstrong\u003eJA-17 rotor assembly\u003c\/strong\u003e (DATE OF MFG. 06\/22), is available at a bargain price with our \u003ca href=\"https:\/\/serviceai.us\/beckman-coulter-instruments\/refurbished-avantijxn\"\u003e\u003cstrong\u003eBeckman Coulter Avanti JXN-30 Centrifuge\u003c\/strong\u003e\u003c\/a\u003e. This package deal is a great value for researchers and biotech \u003cstrong\u003estartups\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eSalient Features of the JA-17 Fixed-Angle Rotor\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKey Specifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Speed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 17,000 RPM\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Relative Centrifugal Force (RCF):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 39,800 × g (at maximum radius)\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRotor Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 14 tubes, each with a maximum capacity of 50 mL\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRotor Angle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25 degrees\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Sample Density:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1.2 g\/mL\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaterial:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Anodized aluminum for corrosion resistance\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eO-rings:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Made of Buna N rubber, providing atmospheric pressure sealing during centrifugation\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e \u003cstrong\u003eDesign and Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEfficient Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Capable of processing up to 700 mL per run, making it suitable for isolating and banding different classes of subcellular organelles.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDurability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Constructed from anodized aluminum, the JA-17 rotor is designed for long-term use, with a 7-year warranty.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be used with a wide range of tube types, including polycarbonate, polyallomer, and polypropylene tubes.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSafety:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Incorporates O-rings and a containment system that has been validated for microbiological aerosol containment, ensuring safe operation even with hazardous materials.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eEase of Use:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The rotor features embedded magnets for easy identification and can be securely fastened using a turn-knob lid.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e \u003cstrong\u003eMaintenance and Care:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Requires regular lubrication of metal threads and O-rings to prevent wear and maintain sealing integrity.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCleaning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Wash the rotor immediately after exposure to corrosive materials and periodically under normal conditions to prevent residue buildup.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDecontamination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be decontaminated using tested solutions such as RadCon Surface Spray, with no damage to the anodized surfaces.\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e The JA-17 rotor is a reliable choice for high-speed centrifugation, offering consistent performance and longevity with proper maintenance.\u003c\/p\u003e\u003ch3\u003eJA-17 Rotor Part Numbers\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRotor Assembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eJA-17 Rotor Assembly with magnets (manufactured January 2002 and later):\u003c\/strong\u003e 369691\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eJA-17 Rotor Assembly (manufactured before December 2001):\u003c\/strong\u003e 341973\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLid and O-rings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eJA-17 Lid Assembly:\u003c\/strong\u003e 369760\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Lid O-ring:\u003c\/strong\u003e 878951\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Hub O-ring:\u003c\/strong\u003e 811656\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eTie-down Kit:\u003c\/strong\u003e 364913\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eHold-down Knob (for use without lid):\u003c\/strong\u003e 354456\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLubricants and Cleaning Supplies:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSpinkote Lubricant (2 oz):\u003c\/strong\u003e 306812\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSilicone Vacuum Grease (1 oz):\u003c\/strong\u003e 335148\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Cleaning Kit:\u003c\/strong\u003e 339558\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eBeckman Solution 555 (1 qt):\u003c\/strong\u003e 339555\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Cleaning Brush:\u003c\/strong\u003e 339379\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRotor Removal Tool:\u003c\/strong\u003e 338896\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eCollar Adapter for Rotor Removal Tool:\u003c\/strong\u003e 338689\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eTubes and Bottles:\u003c\/strong\u003e (Various options available, refer to Table 1 in the document for specific part numbers and descriptions)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003eThese part numbers cover the essential components and accessories for maintaining and operating the JA-17 Fixed Angle Rotor effectively.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333359427721,"sku":"SQ369691","price":7800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/30BB0993-46E3-49F1-B73A-B49995A5C402.webp?v=1772367413"},{"product_id":"jla-10500-rotor","title":"Beckman Coulter JLA-10.500. Fixed-Angle Rotor - NEW \u0026 UNUSED","description":"\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cspan\u003eJLA-10.500 Fixed-Angle Rotor, made of aluminum, comes with six biosafety liquid canisters equipped with secondary liquid closures. This rotor is designed for large-scale initial processing of bacteria or other cells from fermenters, clearing cellular debris from homogenates, or collecting subcellular organelles and protein precipitates Designed to be used with the Avanti J Series and J2 Series centrifuges, it enhances the efficiency and productivity of your laboratory processes.\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThe J-Lite JLA-10.500 Fixed Angle Rotor is a versatile and high-capacity rotor designed for use with Beckman Coulter Avanti® J and J2 series centrifuges (\u003cstrong\u003eNot for Use in Avanti JXN-30\u003c\/strong\u003e). It is ideal for efficiently pelleting cells from large volumes, separating cell particles from tissue homogenates, and purifying low-sedimentation particles such as viruses.\u003c\/p\u003e\u003ch3 style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eMaximum Speed:\u003c\/strong\u003e 10,000 RPM\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eMaximum Relative Centrifugal Force (RCF):\u003c\/strong\u003e 18,600 × g (at maximum radius)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor Angle:\u003c\/strong\u003e 20 degrees\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eNominal Rotor Capacity:\u003c\/strong\u003e 3 liters (6 × 500 mL bottles)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Anodized aluminum rotor body with carbon fiber epoxy composite cannisters\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCritical Speed Range:\u003c\/strong\u003e 600 to 800 RPM\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eWeight (Fully Loaded):\u003c\/strong\u003e 16.2 kg (35.7 lbs)\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eDesign and Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eHigh Capacity:\u003c\/strong\u003e Can process up to 3 liters per run using six 500 mL bottles.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eEfficient Performance:\u003c\/strong\u003e The rotor’s design provides effective sedimentation, making it suitable for a wide range of applications, including large-scale cell harvesting.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eReduced Weight:\u003c\/strong\u003e Approximately 30% lighter than comparable all-aluminum rotors, due to its carbon fiber composite cannisters.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eSafety:\u003c\/strong\u003e Features interchangeable cannisters with closures for secondary containment of samples, ensuring safe operation even with hazardous materials.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eMaintenance and Care:\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRegular Inspection:\u003c\/strong\u003e Check the rotor body, cannisters, and O-rings regularly for damage or wear. Ensure the cannisters are free of deep cracks and that the sealing surfaces are smooth.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eLubrication:\u003c\/strong\u003e Use Spinkote lubricant on metal threads and silicone vacuum grease on O-rings to maintain sealing integrity.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCleaning:\u003c\/strong\u003e Wash with mild detergent, rinse thoroughly with distilled water, and air-dry upside down.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003ePart Numbers for the JLA-10.500 Rotor Assembly\u003c\/h3\u003e\u003col data-rte-list=\"true\"\u003e\n\u003cli\u003e\n\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor Assembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eJLA-10.500 Rotor Assembly with magnets (rotors manufactured Jan. 2002 and later):\u003c\/strong\u003e 369681\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eJLA-10.500 Rotor Assembly (rotors manufactured through Dec. 2001):\u003c\/strong\u003e 360830\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCannisters and Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCannisters (set of 2 with 2 cannister closures):\u003c\/strong\u003e 360828\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCannister Closure Assembly (1):\u003c\/strong\u003e 360842\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCannister Closure O-ring (set of 12):\u003c\/strong\u003e 360848\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCannister Sleeve Washer:\u003c\/strong\u003e 360834\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor Lid and Lubrication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor Lid Assembly:\u003c\/strong\u003e 363334\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eSpinkote Lubricant (2 oz):\u003c\/strong\u003e 306812\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eSilicone Vacuum Grease (1 oz):\u003c\/strong\u003e 335148\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eTri-Flow Lubricant (2 oz):\u003c\/strong\u003e 883371\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCleaning Supplies:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor Cleaning Kit:\u003c\/strong\u003e 339558\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eSolution 555 (1 qt):\u003c\/strong\u003e 339555\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThis rotor offers exceptional performance and safety, with easy maintenance ensuring long-term reliability for demanding centrifugation applications.\u003c\/p\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eSource:\u003c\/strong\u003e\u003c\/p\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eTitle:\u003c\/strong\u003e J-Lite JLA-10.500 Fixed Angle Rotor Assembly Manual\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003ePublisher:\u003c\/strong\u003e Beckman Coulter, Inc., Spinco Business Center, Palo Alto, California\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003ePublication Date:\u003c\/strong\u003e March 2002\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eDocument ID:\u003c\/strong\u003e J-TB-048G\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThis manual provides detailed instructions, safety information, and technical specifications for the J-Lite JLA-10.500 Fixed Angle Rotor, ensuring proper usage and maintenance.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333359460489,"sku":"SQ369681","price":15333.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/upscaled-2x-IMG_2428.webp?v=1772367414"},{"product_id":"jla-81000","title":"Beckman Coulter J-LITE JLA-8.1000 Fixed-Angle Rotor (INSPECTED)","description":"\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThe \u003cstrong\u003eJ-LITE JLA-8.1000\u003c\/strong\u003e is a high-capacity fixed-angle rotor built for \u003cstrong\u003elarge-volume, high-throughput workflows\u003c\/strong\u003e, supporting \u003cstrong\u003e6 × 1,000 mL bottles\u003c\/strong\u003e (6.0 L total). \u003cstrong\u003eThis is a sparingly used J-LITE JLA-8.1000 rotor manufactured in 2023.\u003c\/strong\u003e Designed for dependable pelleting and harvest applications, this rotor is a strong fit for labs that routinely process large batches and want reliable, repeatable performance.\u003c\/p\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThis rotor is a strong match for the Service AI \u003ca href=\"\/beckman-coulter-instruments\/avanti-jxn-26\" target=\"_blank\"\u003eAvanti JXN-26 IVD (MFG 11\/2023) system\u003c\/a\u003e\u003cstrong\u003e.\u003c\/strong\u003e You know your science and preferred workflows—\u003cstrong\u003eService AI provides tested, ready-to-run instrumentation and rotor options that are guaranteed to work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor type:\u003c\/strong\u003e Fixed-angle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 6 × 1,000 mL (6.0 L total)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eMax speed:\u003c\/strong\u003e 8,000 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eMax RCF:\u003c\/strong\u003e 15,970 × g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eRotor angle:\u003c\/strong\u003e 20°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003ek-Factor:\u003c\/strong\u003e 2,482\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eIdeal Uses\u003c\/h3\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThe JLA-8.1000 is well suited for:\u003c\/p\u003e\n\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eLarge-volume pelleting and harvest\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eBacterial and cell culture workflows\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eGeneral-purpose high-capacity separations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eHigh-throughput lab operations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003ePair It with the Avanti JXN-26 IVD (MFG 11\/2023)\u003c\/h3\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eService AI\u003c\/strong\u003e offers a professionally renewed \u003cstrong\u003eAvanti JXN-26 IVD (MFG 11\/2023)\u003c\/strong\u003e with performance up to 26,000 rpm, 82,000 × g, and 6.0 L maximum capacity. The JLA-8.1000 complements that system by enabling efficient 1 Liter bottle processing for labs that already run high-volume protocols.\u003c\/p\u003e\n\u003cp data-rte-preserve-empty=\"true\" style=\"white-space: pre-wrap;\"\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThe JLA-8.1000 rotor can be used in Avanti JXN-26, J-26S XP series, Avanti J-26 XP series, and in discontinued Avanti J-20 series and Avanti J-20 XP series centrifuges only.\u003c\/p\u003e\n\u003ch3 style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThe Service AI Advantage\u003c\/h3\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eService AI supports scientists with trusted centrifuge platforms, careful professional shipment, and knowledgeable technical support, helping labs add the rotor capacity they already rely on—backed by tested performance and real-world readiness.\u003c\/p\u003e\n\u003ch3 style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eCall to Action\u003c\/h3\u003e\n\u003cp style=\"white-space: pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eContact us today for pricing and availability on the JLA-8.1000 (MFG 11\/2023)\u003c\/strong\u003e and to request a quote \u003cstrong\u003ealongside the Avanti JXN-26 IVD (MFG 2023)\u003c\/strong\u003e if you’re building a complete high-volume configuration.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333359526025,"sku":"SQ3005736","price":16400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/IMG_6470_707ecca5-60ee-4275-9012-cdfdbb7ec41d.webp?v=1772367415"},{"product_id":"sw-41ti-rotor","title":"Beckman SW 41 Swinging Bucket Rotor (INSPECTED)","description":"\u003cp\u003e\u003cstrong\u003eSOLD — This item was previously in stock at Service AI and has been sold.\u003c\/strong\u003e It remains listed for reference only and is not available for purchase. Please see our \u003ca href=\"\/collections\/rotors-accessories\"\u003ecurrent listings\u003c\/a\u003e for instruments and rotors available now. Please contact Service AI to inquire about availability.\u003c\/p\u003e\u003cp class=\"\" style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eRotor Assembly: No. 331362. SW 41 Ti Rotor and Bucket Set. Also sold for a deal as a package with our \u003ca target=\"_blank\" href=\"\/products\/refurbished-xpn80\"\u003e\u003cstrong\u003e\u003cspan\u003eBeckman Coulter Optima XPN-80 ultracentrifuge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e. This rotor package shipped with PN.331313, Bucket Holder Rack; PN. 332400,  Rotor Stand and the blue satin rotor cover.\u003c\/p\u003e\u003cp class=\"\" style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cspan\u003eThe SW 41 Rotor, a swinging-bucket type, accommodates up to six tubes and reaches speeds of up to 41,000 rpm. Compatible with Beckman Coulter Class H, R, and S Preparative Ultracentrifuges, swinging bucket rotors are perfect for rate zonal studies requiring maximum resolution, or pelleting tasks where centered pellet formation is crucial. They are also versatile with all gradient types and configurations.\u003c\/span\u003e\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333361655945,"sku":"SQ1436033","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/IMG_1784.webp?v=1772367447"},{"product_id":"type-502-ti-rotor","title":"Beckman Type 50.2 Ti Rotor (INSPECTED)","description":"\u003cp\u003e\u003cstrong\u003eSOLD — This item was previously in stock at Service AI and has been sold.\u003c\/strong\u003e It remains listed for reference only and is not available for purchase. Please see our \u003ca href=\"\/collections\/rotors-accessories\"\u003ecurrent listings\u003c\/a\u003e for instruments and rotors available now. Please contact Service AI to inquire about availability.\u003c\/p\u003e\u003cp class=\"\"\u003eThe Type 50.2 Titanium rotor is rated for 50 000 rpm. It is a fixed angle Beckman Coulter rotor designed to centrifuge up to twelve tubes at a 24-degree angle to the axis of rotation. This rotor shipped with a \u003cstrong\u003enew over-speed disk and o-rings,\u003c\/strong\u003e and can be used In Beckman Coulter Class G, H, R, and S Preparative Ultracentrifuges.\u003c\/p\u003e\u003cp class=\"\"\u003eThis rotor will work well with the \u003ca href=\"\/products\/refurbished-l-100k-ultracentrifuge\"\u003eOptima L-100K ultracentrifuge\u003c\/a\u003e.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333361754249,"sku":"SQ0016050","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/20190714_204324458_iOS.webp?v=1772367449"},{"product_id":"beckman-coulter-j-lite-jla-16-250-rotor-mfg-2023","title":"Beckman Coulter J-LITE JLA-16.250 Rotor (MFG 2023)","description":"\u003cp\u003e\u003cstrong\u003eAvailable for Purchase: A sparingly used Beckman Coulter J-LITE JLA-16.250 fixed-angle rotor, manufactured in 2023.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe JLA-16.250 is designed and manufactured by \u003ca href=\"https:\/\/store.beckman.com\/p\/jla-16250-fixed-angle-rotor\/363934\" rel=\"noopener\" target=\"_blank\"\u003eBeckman Coulter\u003c\/a\u003e. It has six 250 mL positions, a nominal capacity of 1.5 liters, and a maximum speed of 16,000 rpm in compatible Avanti J series centrifuges. Applications include pelleting cells and separating cell particles from tissue homogenates.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Beckman Coulter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e J-LITE JLA-16.250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear of manufacture:\u003c\/strong\u003e 2023\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Sparingly used\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor type:\u003c\/strong\u003e Fixed-angle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor angle:\u003c\/strong\u003e 25°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 6 × 250 mL (1.5 L nominal total)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum speed, Avanti J series:\u003c\/strong\u003e 16,000 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum speed, J2 series:\u003c\/strong\u003e 14,000 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum RCF:\u003c\/strong\u003e 38,400 × g at a radius of 134 mm and 16,000 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ek-factor:\u003c\/strong\u003e 1,090 at maximum speed in Avanti J series; 1,400 at maximum speed in J2 series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum solution density:\u003c\/strong\u003e 1.2 g\/mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor material:\u003c\/strong\u003e Aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmpty rotor weight:\u003c\/strong\u003e 10.3 kg (22.7 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor weight with maximum sample mass:\u003c\/strong\u003e 13.2 kg (29.1 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum allowable imbalance of opposing loads:\u003c\/strong\u003e 10 grams\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical speed range:\u003c\/strong\u003e 600–800 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor entry code, microprocessor-controlled J2 series:\u003c\/strong\u003e 14\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Centrifuge Available from Service AI\u003c\/h3\u003e\n\u003cp\u003eThis rotor can be paired with the \u003ca href=\"\/products\/avanti-jxn-26\" rel=\"noopener\" target=\"_blank\"\u003eBeckman Coulter Avanti JXN-26 IVD\u003c\/a\u003e listed on our website. The JLA-16.250 provides six 250 mL positions and a maximum speed of 16,000 rpm on this platform. Contact us for a quotation for the rotor alone or with the centrifuge.\u003c\/p\u003e\n\u003cp\u003eThe rotor is also designed for compatible Beckman Coulter J2 and Avanti J series centrifuges. Compatibility and operating limits must be checked for the specific centrifuge, bottles, and adapters used. Follow Beckman Coulter’s rotor and centrifuge instructions and the applicable labware instructions. Speed reduction may be required based on sample density and operating conditions.\u003c\/p\u003e\n\u003ch3\u003eService AI Support\u003c\/h3\u003e\n\u003cp\u003eThe Service AI team brings service training and hands-on experience with laboratory centrifuges and rotors. We can assist with compatibility questions, bottle and adapter requirements, and details about this unit’s condition and included components.\u003c\/p\u003e\n\u003ch3\u003eRelated Reading\u003c\/h3\u003e\n\u003cp\u003eFor an overview of medium- and large-volume rotor configurations on the JXN-26, read our \u003ca href=\"\/blogs\/guide-to-centrifugation\/leveraging-the-beckman-coulter-avanti-jxn-26-with-jla-16250-and-jla-81000-rotors\" rel=\"noopener\" target=\"_blank\"\u003eAvanti JXN-26 Guide: JLA-16.250 \u0026amp; JLA-8.1000 Rotors\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor guidance on cleaning, handling, inspection, and service-life considerations, see \u003ca href=\"\/blogs\/guide-to-centrifugation\/the-complete-guide-to-centrifuge-rotor-care-inspection-and-retirement\" rel=\"noopener\" target=\"_blank\"\u003eThe Complete Guide to Centrifuge Rotor Care, Inspection, and Retirement\u003c\/a\u003e. Regular care and inspection remain important even for a sparingly used rotor.\u003c\/p\u003e\n\u003ch3\u003ePricing and Purchase Inquiries\u003c\/h3\u003e\n\u003cp\u003eFor pricing or a formal quotation, email \u003ca href=\"mailto:support@serviceai.us\"\u003esupport@serviceai.us\u003c\/a\u003e. Please include your centrifuge model and any configuration questions.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":48495173664905,"sku":null,"price":9650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/Beckman_JLA-16.250_Centrifuge_Rotor.jpg?v=1791081686"},{"product_id":"beckman-coulter-tla-120-1-fixed-angle-rotor","title":"Beckman Coulter TLA-120.1 Fixed-Angle Rotor","description":"\u003cp\u003eThe \u003cstrong\u003eBeckman Coulter TLA-120.1 fixed-angle rotor\u003c\/strong\u003e is offered by Service AI for the Optima MAX-TL tabletop ultracentrifuge. The rotor has seen very little use and is in excellent condition — clean and well kept. Service AI's Beckman-trained service experts will inspect the rotor before shipment. Our specialists bring technical knowledge of ultracentrifuge systems, rotor compatibility, tubes and labware, and service to help your laboratory make an informed purchasing decision.\u003c\/p\u003e\n\u003ch2\u003eRotor pricing and instrument package\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecial instrument and rotor package:\u003c\/strong\u003e This TLA-120.1 is the matched rotor for the Optima MAX-TL tabletop ultracentrifuge we currently have in stock. Bought together as a package, the rotor is priced into the package at $5,995 — a saving of $4,000 against buying it on its own. We have just one of these rotors, and package buyers have first call on it: if the package sells first, this listing will be withdrawn. Contact Service AI for package pricing and a quotation tailored to your laboratory's configuration and installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTLA-120.1 rotor pricing:\u003c\/strong\u003e The rotor is also available on its own at $9,995. Beckman Coulter's list price for this rotor assembly (PN 362224) is $11,200. The rotor is priced separately from the instrument.\u003c\/p\u003e\n\u003cp\u003eFor instrument pricing and technical specifications, visit our \u003ca href=\"\/products\/beckman-coulter-optima-max-tl-ultracentrifuge\"\u003eBeckman Coulter Optima MAX-TL Tabletop Ultracentrifuge listing\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor:\u003c\/strong\u003e Beckman Coulter TLA-120.1 fixed-angle rotor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor type:\u003c\/strong\u003e Fixed-angle (TL-series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum rotational speed:\u003c\/strong\u003e 120,000 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum RCF:\u003c\/strong\u003e 627,000 x g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 14 x 0.5 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Beckman Coulter Optima MAX-XP, MAX-TL, MAX, MAX-E, TL, TLX, and TL-100 tabletop ultracentrifuges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor serial number:\u003c\/strong\u003e 20U1381\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Excellent condition with very little use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRotor inspection\u003c\/h2\u003e\n\u003cp\u003eBefore shipment, our Beckman-trained service experts will complete a visual and mechanical inspection of the rotor, including the rotor body, lid, and sealing surfaces. Request the available rotor history as part of your purchasing review.\u003c\/p\u003e\n\u003ch2\u003eConfiguration and purchasing information\u003c\/h2\u003e\n\u003cp\u003eContact Service AI to confirm compatible tubes and labware for your application. Request an itemized quotation specifying the rotor, your selected tubes and labware, and — if purchasing together with the Optima MAX-TL — professional installation at your laboratory's location. Rotor inclusion, installation scope, and associated charges will be stated in your quotation.\u003c\/p\u003e\n\u003ch2\u003eRelated reading from our Guide to Centrifugation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/understanding-centrifuge-rotors\"\u003eUnderstanding Centrifuge Rotors: A Comprehensive Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/the-complete-guide-to-centrifuge-rotor-care-inspection-and-retirement\"\u003eThe Complete Guide to Centrifuge Rotor Care, Inspection, and Retirement\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/what-rpm-can-one-use-with-a-beckman-coulter-rotor-to-obtain-the-desired-g-force\"\u003eDetermining RPM for Desired 'g' Force with a Beckman Coulter Rotor\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/the-benchtop-ultracentrifuge-in-nanoparticle-research-extracellular-vesicles-and-the-optima-max-tl\"\u003eThe Benchtop Ultracentrifuge in Nanoparticle Research\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":48702150213769,"sku":null,"price":9995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/tla-120-1-rotor-1-lid-top.jpg?v=1792279167"},{"product_id":"beckman-coulter-vti-50-1-vertical-tube-rotor","title":"Beckman Coulter VTi 50.1 Vertical Tube Rotor","description":"\u003cp\u003eThe \u003cstrong\u003eBeckman Coulter VTi 50.1 vertical tube rotor\u003c\/strong\u003e provides a high-capacity option for isopycnic density gradient separations in compatible Beckman Coulter Optima floor-standing ultracentrifuges. This lightly used rotor is clean, well maintained, and in excellent condition. \u003cstrong\u003eRotor plugs and the Beckman Coulter torque wrench assembly (PN 369791) are included\u003c\/strong\u003e for tightening the plugs to the specified torque.\u003c\/p\u003e\n\u003cp\u003eService AI's Beckman-trained service specialists inspect and check each rotor upon acquisition. We can also help you confirm instrument compatibility and select tubes and labware suited to your protocol.\u003c\/p\u003e\n\u003ch2\u003eRequest a quotation\u003c\/h2\u003e\n\u003cp\u003ePlease use the request-a-quote option to obtain a formal quotation for your laboratory. We can also quote compatible tubes and labware for your application.\u003c\/p\u003e\n\u003cp\u003eThis rotor, serial number 22U201, was manufactured in 2022.\u003c\/p\u003e\n\u003ch2\u003eDesigned for equilibrium density gradient separations\u003c\/h2\u003e\n\u003cp\u003eThe VTi 50.1 holds \u003cstrong\u003e12 × 39 mL tubes, for a total capacity of 468 mL per run\u003c\/strong\u003e. Its vertical tube geometry provides a short radial sedimentation path across the width of each tube rather than along its length. This geometry can reduce the time required to reach equilibrium compared with swinging-bucket or fixed-angle configurations, depending on the sample and gradient conditions.\u003c\/p\u003e\n\u003cp\u003eApplications include plasma lipoprotein separations using the single vertical spin method, density gradient purification of viruses and viral vectors, and DNA banding in cesium chloride gradients. Rotor speed, gradient composition, tube selection, and run conditions should be matched to your established protocol.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor:\u003c\/strong\u003e Beckman Coulter VTi 50.1 vertical tube rotor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor type:\u003c\/strong\u003e Vertical tube\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer rotor package part number:\u003c\/strong\u003e C78759. Items supplied with this pre-owned rotor are stated above.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum rotational speed:\u003c\/strong\u003e 50,000 rpm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum RCF:\u003c\/strong\u003e 251,000 × g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 12 × 39 mL (468 mL total)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube format:\u003c\/strong\u003e OptiSeal and Quick-Seal tubes, 25 × 89 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ek factor:\u003c\/strong\u003e 34\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Beckman Coulter Class R and S ultracentrifuges. Confirm your instrument configuration and software requirements before use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor serial number:\u003c\/strong\u003e 22U201\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Excellent condition with very little use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor manufacturer specifications, visit \u003ca href=\"https:\/\/store.beckman.com\/p\/vti-501-vertical-angle-rotor\/c78759\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBeckman Coulter's VTi 50.1 rotor specifications\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRotor inspection\u003c\/h2\u003e\n\u003cp\u003eOur inspection covers the rotor body and sealing surfaces, plug threads and hexagonal torque sockets, and spacers. We assess wear and damage that could affect secure tightening to the manufacturer's specified torque. Damaged plugs or spacers are replaced before the rotor is offered for use. Inspection findings and any available usage history can be discussed as part of your technical review.\u003c\/p\u003e\n\u003ch2\u003ePlanning your configuration\u003c\/h2\u003e\n\u003cp\u003eThe VTi 50.1 supports compatible OptiSeal and Quick-Seal tubes.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, please confirm with Beckman Coulter that your centrifuge model and installed software support the VTi 50.1 rotor. Any required software update should be arranged directly with Beckman Coulter service.\u003c\/p\u003e\n\u003cp\u003eNot sure whether your instrument supports this rotor? Send us your centrifuge model, serial number, and a photo of the software-version screen. We can help gather the information needed for Beckman Coulter service to confirm compatibility and any update requirements.\u003c\/p\u003e\n\u003ch2\u003eRelated reading from our Guide to Centrifugation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/understanding-centrifuge-rotors\"\u003eUnderstanding Centrifuge Rotors: A Comprehensive Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/the-complete-guide-to-centrifuge-rotor-care-inspection-and-retirement\"\u003eThe Complete Guide to Centrifuge Rotor Care, Inspection, and Retirement\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/guide-to-centrifugation\/introduction-to-centrifugation\"\u003eIntroduction to Centrifugation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":48712937734281,"sku":null,"price":14995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/vti-50-1-rotor-1-hero.jpg?v=1792356851"}],"url":"https:\/\/serviceai.us\/collections\/rotors-accessories.oembed","provider":"Service AI","version":"1.0","type":"link"}