{"product_id":"avanti-jxn-26","title":"Beckman Coulter Avanti JXN-26 IVD","description":"\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003eService AI offers a recent-vintage, professionally renewed Beckman Coulter Avanti JXN-26 IVD (MFG: 2023-11-13) \u003c\/strong\u003e— a high-performance, floor-model centrifuge built for dependable, high-throughput workflows in modern lab environments. With performance up to \u003cstrong\u003e26,000 rpm\u003c\/strong\u003e, \u003cstrong\u003e82,000 × g\u003c\/strong\u003e, and \u003cstrong\u003e6.0 L maximum capacity\u003c\/strong\u003e, the JXN-26 is a strong fit for labs that need consistent results across daily protocols and larger-volume applications. Customers can customize their setup with \u003cstrong\u003eoptional\u003c\/strong\u003e rotor choices based on workflow needs, including two premium \u003cstrong\u003eJ-LITE\u003c\/strong\u003e fixed-angle options manufactured in 2023.\u003c\/p\u003e\u003ch3 style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eCore System Highlights (Avanti JXN-26; REF: B38619)\u003c\/h3\u003e\u003cul data-rte-list=\"true\"\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eIVD-compatible build for regulated environments\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eMax speed: 26,000 rpm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eMax RCF: up to 82,000 × g\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eMax capacity: 6.0 L\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eFRS + SR drive for quick, quiet, cool operation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eUp to 1000 stored programs for repeatable workflows and shared-lab efficiency\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eRotor Options Available for Purchase (MFG 2023)\u003c\/h3\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003e\u003ca href=\"\/products\/beckman-coulter-j-lite-jla-16-250-rotor-mfg-2023\"\u003eJ-LITE JLA-16.250\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003eA lightweight, high-performance fixed-angle rotor ideal for routine pelleting and general-purpose separations.\u003cbr\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 6 × 250 mL (1.5 L total)\u003c\/p\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003e\u003cstrong\u003e\u003ca href=\"\/products\/jla-81000\"\u003eJ-LITE JLA-8.1000\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003eA high-capacity rotor designed for large-volume processing and 1 L bottle workflows.\u003cbr\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 6 × 1000 mL (6.0 L total)\u003c\/p\u003e\n\u003ch3\u003eAdditional Compatible Rotor Listings\u003c\/h3\u003e\n\u003cp\u003eFor other sample volumes and workflows, explore these separately listed fixed-angle rotor options for the Avanti JXN-26:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/jla-10500-rotor\"\u003eJ-LITE JLA-10.500 Rotor — New \u0026amp; Unused\u003c\/a\u003e: 6 × 500 mL (3 L total), up to 10,000 rpm.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ja-17-rotor-assembly\"\u003eJA-17 Fixed-Angle Rotor — Inspected\u003c\/a\u003e: 14 × 50 mL (700 mL total), up to 17,000 rpm.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ja-1450-rotor\"\u003eJA-14.50 Rotor with Dual-Locking Lid — Inspected\u003c\/a\u003e: 16 × 50 mL (800 mL total), up to 14,000 rpm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRotors are optional purchases, not automatically included with the centrifuge. Contact Service AI for current availability and a configuration quotation. Confirm the specific rotor assembly, labware, adapters, and operating limits against the manufacturer's instructions; speed reductions may apply depending on sample density and other conditions.\u003c\/p\u003e\n\u003ch3 style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eSeamless Installation and Support\u003c\/h3\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eOur expert team ensures a seamless installation process included in the price for the continental United States. We also offer worldwide installation and service support to meet your specific needs.\u003c\/p\u003e\u003ch3 style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eThe Service AI Advantage\u003c\/h3\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eService AI supports scientists with trusted centrifuge platforms, careful professional shipment, and knowledgeable technical support, helping labs configure the right system and rotor selections with confidence.\u003c\/p\u003e\u003cp style=\"white-space:pre-wrap;\" data-rte-preserve-empty=\"true\"\u003eYou know the science. We deliver tested, guaranteed performance. Contact us today for a comprehensive quote on the JXN-26 and optional 2023 J-LITE rotors.\u003c\/p\u003e\n\u003ch3\u003eConfigure Your JXN-26 for Your Workflow\u003c\/h3\u003e\n\u003cp\u003eStart with your sample volume, required relative centrifugal force (RCF), and preferred tubes or bottles when choosing a rotor. The optional JLA-16.250 offers six 250 mL positions, while the JLA-8.1000 offers six 1 L positions for larger-volume processing. Rotor choice should reflect your protocol, not simply the centrifuge's maximum speed. Confirm instrument compatibility and the operating limits of the rotor, tubes, bottles, and adapters before use.\u003c\/p\u003e\n\u003cp\u003eFor a practical introduction to rotor types and selection, read LabPundit's \u003ca href=\"\/blogs\/guide-to-centrifugation\/the-start-up-researchers-guide-to-centrifuge-rotors\"\u003eA Startup Guide to Centrifuge Rotors\u003c\/a\u003e. It explains how sample volume, separation goals, consumables, and budget shape your choice.\u003c\/p\u003e\n\u003ch3\u003eProtect Your Rotor Investment\u003c\/h3\u003e\n\u003cp\u003eRoutine cleaning, appropriate storage, and inspection are important parts of keeping your centrifugation workflow dependable. Follow the specific rotor operator's manual for approved cleaning methods, inspection requirements, and service-life limits. If you find corrosion, pitting, cracks, or other damage, stop using the rotor and seek a qualified assessment.\u003c\/p\u003e\n\u003cp\u003eExplore \u003ca href=\"\/blogs\/guide-to-centrifugation\/the-complete-guide-to-centrifuge-rotor-care-inspection-and-retirement\"\u003eThe Complete Guide to Centrifuge Rotor Care, Inspection, and Retirement\u003c\/a\u003e for a closer look at care practices, warning signs, and retirement considerations.\u003c\/p\u003e\n\u003ch3\u003eCommon Centrifugation Questions\u003c\/h3\u003e\n\u003cp\u003eNeed background on RPM versus RCF, tube fill volumes, consumable reuse, or rotor identification? Our \u003ca href=\"\/blogs\/guide-to-centrifugation\/centrifuge-faq-essential-information-for-users\"\u003eCentrifuge FAQ: Essential Information for Users\u003c\/a\u003e provides an overview. Use these educational resources alongside the current JXN-26 and rotor-specific operator manuals, which govern your actual operating procedures.\u003c\/p\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":45333356707977,"sku":"SQB38619","price":39900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7196\/2761\/files\/IMG_6447.jpg?v=1772367375","url":"https:\/\/serviceai.us\/products\/avanti-jxn-26","provider":"Service AI","version":"1.0","type":"link"}